Article ID Journal Published Year Pages File Type
3928671 European Urology 2007 6 Pages PDF
Abstract

ObjectivesTo report the utilization of a modified Endo GIA vascular stapler to obtain the full length of the renal vein during transperitoneal laparoscopic live donor right nephrectomy.MethodsWe used a modified Endo GIA stapler, in which the triple staggered rows of staples were removed from the kidney donor side to obtain the full length of the right renal vein. This technique has currently been used in nine consecutive transperitoneal laparoscopic right donor nephrectomies.ResultsWith this technique, the entire right renal vein length was harvested in all cases, without vascular complications. Mean renal warm ischemia time from clamping of the renal vessels to cold perfusion was 135 s, and mean receptor postoperative glomerular filtration rate after 30 d was 67.3 ml/min. There were no graft losses.ConclusionsA novel technique for laparoscopic live donor right nephrectomy is described. It allows harvesting the full length of the right renal vein in a safe and feasible way without compromising warm ischemia time.

Related Topics
Health Sciences Medicine and Dentistry Obstetrics, Gynecology and Women's Health
Authors
, , , , , , , ,