Abstract
Insertion of HDRB catheters exerts substantial acute volumetric distortion on the prostate. EBRT planning performed on the basis of pre-HDRB imaging only inherently risks underdosing tumor. Planning adjustments based on repeat CT, or dedicated post-HDBT planning, is warranted for men managed with HDRB before EBRT.