Article ID Journal Published Year Pages File Type
3981665 Clinical Radiology 2014 6 Pages PDF
Abstract

•A standardized procedure for diagnostic imaging is essential for body packers.•The clinical and legal importance of an accurate diagnosis cannot be overstated.•Projection radiography failed in terms of reliability and validity.•Radiation dose of CT can be decreased to nearly the same level as an x-ray image.

AimTo analyze the clinical value and radiation dose of plain x-rays and CT in examining patients suspected of ingesting drug-filled packets.Materials and methodsThirty-eight patients with suspected internal concealment of drug-filled packets who were examined with plain x-rays or CT or both were included in the study. CT studies were performed using low-dose and standard-dose techniques. All radiographic images were analysed by two radiologists regarding identification of the packets and estimating the effective radiation dose from standard- and low-dose CT versus conventional x-ray examinations. Descriptive calculations were made regarding the number and density of packs and radiation dosage. The diagnostic performance of both radiologists with standard- and low-dose CT was calculated by analysing differences in the mean number of packs found.ResultsThirty-one patients were positively identified as body packers with an average of 13 packs (min: n = 1, max: n = 58, total: n = 390); seven patients were not concealing drug packets. X-ray images were taken of 24 patients prior to CT, thus allowing a direct comparison between the two methods. The correct diagnosis was made in 42%, in 33% the radiologists were uncertain, and in 25% of drug packets were either not or wrongly identified. X-ray imaging had a positive predictive value of 20% with a negative predictive value of 81%. A total of 55 CT examinations were performed on all patients with a mean effective dose of 2 mSv (low dose) versus 9.3 mSv (standard dose). The visibility of packets on low-dose CT images compared to high-dose CT was not reduced: the radiologists identified 385 and 381 of the packets, respectively, with no difference regarding the examination technique (p = 0.24 and p = 0.253, respectively). The radiodensity of all drug-filled packets at CT ranged from 26–292 HU (mean 181.2 HU).ConclusionX-ray imaging of supposed body packers leads to a significant risk of diagnostic errors and additional need for CT. Instead, a single abdominal low-dose CT examination will deliver the correct diagnoses in most cases, leading to safe clinical management of the suspects.

Related Topics
Health Sciences Medicine and Dentistry Oncology
Authors
, , , , , ,