Article ID Journal Published Year Pages File Type
3983736 Clinical Radiology 2006 5 Pages PDF
Abstract

AIMTo evaluate the image quality of axial and coronal reformats obtained from isotropic resolution 40-channel chest computed tomography (CT) examinations.METHODS AND MATERIALSThirty consecutive patients with intravenous contrast-enhanced chest CT examinations using a 40-channel CT machine were enrolled for the study. The raw data were reconstructed into two sets of source axial images: 0.9 mm section width and 0.45 mm reconstruction interval (isotropic resolution) and 4 mm section width with 3 mm reconstruction interval (anisotropic resolution; group A). The isotropic data set was reformatted into axial and coronal stacks (groups B and C, respectively) with 4 mm section width and 3 mm interval. Three independent readers evaluated stacks A to C using a three-point scale for resolution of right lower lobe segmental bronchi, edge sharpness of major and minor fissures, respiratory motion artefact, reconstruction artefact, noise and overall image quality.RESULTSThe sharpness of fissures scored significantly higher with the coronal reformats (group C) compared with the axial image sets (groups A and B) (p<0.01). Noise in group A scored significantly lower than groups B or C (p<0.01). For other parameters there was no statistical difference between the groups. There was substantial or excellent agreement between the reviewers.CONCLUSIONIsotropic imaging of the chest allows creation of reformats with similar image quality as similar thickness axial source images. These reformats are probably of sufficient quality to form the basis of clinical interpretation.

Related Topics
Health Sciences Medicine and Dentistry Oncology
Authors
, , , , , ,