Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
3983942 | Clinical Radiology | 2006 | 5 Pages |
AIMTo investigate the feasibility of imaging lower limb deep vein thrombosis using magnetic resonance imaging (MRI) at 3.0 T magnetic field strength with an optimized a T1 magnetization prepared rapid gradient echo technique (MP-RAGE) in patients with normal volunteers as controls.MATERIALS AND METHODSPatients with deep vein thrombosis (n=4), thrombophlebitis (n=2) and healthy volunteers (n=9) were studied. MRI of the distal thigh and upper calf was performed at 3.0 T with MP-RAGE using two pre-pulses to suppress blood and fat (flip angle 15°, echo time 5 ms, and repetition time 10 ms). A qualitative analysis was performed for detection of thrombi and image quality. Contrast-to-noise ratios were determined in thrombosed and patent veins.RESULTSThrombi were clearly visible as high-signal intensity structures with good suppression of the anatomical background. A blinded reader accurately diagnosed 15 out of 16 cases. The contrast-to-noise ratio measurements showed a positive contrast of thrombus over background muscle 16.9 (SD 4.3, 95% CI: 12.5–21.3) and a negative contrast of the lumen to muscle in patent veins of normal volunteers −7.8 (SD 4.3, 95% CI: −11.1 to −4.5), with p=0.0015.CONCLUSIONThrombi generate high signal intensity at 3.0 T allowing for their direct visualization if flowing blood, stationary blood and fat are sufficiently suppressed. This preliminary data supports the development of these techniques for other vascular applications.