Article ID Journal Published Year Pages File Type
4008616 Archivos de la Sociedad Española de Oftalmología (English Edition) 2013 4 Pages PDF
Abstract

Clinical caseNo intraocular biopsy technique is free of risk and all have the possibility of giving false negatives due to the difficulty in obtaining a sufficient sample.A modified chorioretinal biopsy was performed on a patient with suspected choroidal melanoma after negative biopsy with 25 G vitrectomy. In addition to removing a solid fragment of tumor material using bimanual surgery, material from the lesion was obtained with the vitreotome to perform cytology, which confirmed the diagnosis of melanoma.DiscussionCytology obtained through the vitreotome in association with removing a solid sample of the choroidal lesion may improve the efficiency of intraocular biopsy.

ResumenCaso clínicoNinguna técnica de biopsia intraocular es inocua y todas tienen posibilidad de falsos negativos por la dificultad para obtener una muestra suficiente.Paciente con sospecha de melanoma tras biopsia negativa con vitrectomía 25 G. Se realiza biopsia coriorretiniana modificada en la que además de extraerse un fragmento mediante cirugía bimanual, se obtiene material de la lesión con vitreotomo para realizar citología, confirmando el diagnóstico de sospecha de melanoma de coroides.DiscusiónLa asociación de una citología obtenida con vitreotomo de una lesión coroidea asociada a la escisión de un fragmento de la lesión puede mejorar la eficacia de la biopsia intraocular.

Related Topics
Health Sciences Medicine and Dentistry Ophthalmology
Authors
, , , , , ,