Article ID Journal Published Year Pages File Type
4020937 Journal of Cataract & Refractive Surgery 2007 4 Pages PDF
Abstract

We describe an intraocular lens (IOL) fixation technique that combines suture-in-needle and scleral tunnel techniques. A 10-0 polypropylene suture is inserted into the barrel of a 27-gauge sharp needle to tie the IOL haptic, and scleral tunnels are created to bury the knots for transscleral IOL fixation. The modification of the traditional scleral fixation technique simplifies the creation of a scleral covering and decreases harmful manipulations of the needle passing through the vitreous cavity.

Related Topics
Health Sciences Medicine and Dentistry Ophthalmology