Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4032802 | Survey of Ophthalmology | 2012 | 18 Pages |
Abstract
Intraocular lens (IOL) confusions and errors are among the most common postoperative adverse events. Errors may occur at any stage from the decision to operate to the insertion of the IOL. The most common errors occur during IOL selection pre-operative preparation (anaesthesia given before recognition that the intended IOL is not available), or intraoperatively (wrong IOL implanted because of confusion in the operating room). We review the mechanisms of errors reported in the literature and describe the experience at The Royal Victorian Eye and Ear Hospital. We also describe the implementation of an error-detection protocol and provide qualitative data on its performance.
Related Topics
Health Sciences
Medicine and Dentistry
Ophthalmology
Authors
Ehud Zamir, Katarina Beresova-Creese, Linda Miln,