Article ID Journal Published Year Pages File Type
4046990 Arthroscopy: The Journal of Arthroscopic & Related Surgery 2008 5 Pages PDF
Abstract

PurposeThe purpose of this study was to define a safe angle for suture anchor insertion during acetabular labral repair that will facilitate anchor placement within bone and prevent penetration into the hip joint.MethodsNine acetabuli were harvested. Anatomic measurements were performed at the anterosuperior quadrant. Electronic calipers were used to measure acetabular bone. “Safe angle” measurements were obtained with suture anchor drills and a protractor. Comparisons between groups were calculated with a 1-way analysis of variance. The Tukey post-hoc analysis was completed for all significant analysis of variance results.ResultsLabral insertion point distances and acetabular bone widths at the labral insertion did not statistically differ. Mean “danger angles” ranged from 17.0° to 23.8°. Safe angle measurements ranged from 20.1° to 27.6°.ConclusionsThe extracapsular labral insertion, located between 2.3 and 2.6 mm from the rim of the anterosuperior acetabulum, is offered as a starting point for insertion of anchors sized less than 3.0 mm. The danger angle and safe angle of anchor insertion serve as guidelines that may improve fixation in bone and lessen intra-articular penetration. A target angle of 10° is recommended.Clinical RelevanceThe danger angle and safe angle may be referenced intraoperatively, during imaging and suture anchor insertion, to assure anchor placement within bone and prevent intra-articular penetration. A target angle of 10° is safe and easily remembered.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, ,