Article ID Journal Published Year Pages File Type
4047038 Arthroscopy: The Journal of Arthroscopic & Related Surgery 2008 4 Pages PDF
Abstract

We present a method for single–Achilles allograft medial collateral ligament (MCL) and posterior cruciate ligament (PCL) reconstruction that eliminates the risk of tunnel intersection, stiffens the construct, and maximizes utilization of allograft tissue. An Achilles tendon allograft is prepared with an 11- to 12-mm bone plug with a gradual taper to 7 mm over approximately 15 cm. A transtibial PCL tunnel is created under fluoroscopic and arthroscopic guidance. The femoral tunnel is prepared in an “outside-in” fashion under direct arthroscopic visualization, originating at the anatomic origin of the MCL on the medial epicondyle and entering the joint at the anatomic origin of the anterolateral bundle of the PCL. The Achilles graft is pulled into the joint through the tibial tunnel and routed into the femoral tunnel so that the soft tissue exits at the medial epicondyle. The bone plug is fluoroscopically guided to the posterior aperture of the tibial tunnel and fixed with a bioabsorbable interference screw. The pretensioned graft is fixed in the femoral tunnel via interference screw fixation with the knee in 90° of flexion. The isometric position of the MCL insertion is identified with a K-wire isometer, and the graft is fixed in place at this point by use of an interference screw or screw and washer.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, ,