Article ID Journal Published Year Pages File Type
4050988 Clinical Biomechanics 2010 6 Pages PDF
Abstract

BackgroundThe purpose of the study was to investigate the changes in gait patterns and clinical measurements following treatment with a novel biomechanical device on patients with knee osteoarthritis.MethodsForty six patients with bilateral knee osteoarthritis were analyzed. Patients completed a gait test, Western Ontario and McMaster Osteoarthritis Index (WOMAC) questionnaire and SF-36 Health Survey at baseline and after 12 weeks. The biomechanical device was individually calibrated to each patient at baseline to allow training under reduced pain.FindingsGait velocity, step length and single limb support improved significantly and toe out angle decreased significantly (10%, 6%, 1% and 2%, respectively). WOMAC-Pain and WOMAC-Function significantly decreased (26% and 34%, respectively), and SF-36 score significantly increased following the 12 weeks of treatment.InterpretationOur results suggest an overall improvement in the gait patterns, level of pain and level of function of patients with knee osteoarthritis following 12 weeks of treatment with the novel biomechanical device.The study is registered at clinicaltrials.gov, identifier NCT00767780, http://www.clinicaltrials.gov/ct/show/NCT00767780.