Article ID Journal Published Year Pages File Type
4051687 Clinical Biomechanics 2006 5 Pages PDF
Abstract

BackgroundFracture healing has been linked to both the magnitude and distribution of mechanical stresses on the healing fracture tissues. However, direct clinical measurement of in vivo tibial axial loading is not possible.MethodsUsing computed tomography images, force plate data and recorded 3D interfragmentary micromovements, accurate 3D finite element models of a healing human tibial fracture were generated at 7, 10, and 16 weeks post-fracture and used to calculate longitudinal tibial forces and external fixator load-sharing during bilateral stance and walking.FindingsTibial load-sharing by the fixator decreased significantly as the fracture tissues developed even moderate stiffness, while tibial load increased steadily towards normal.InterpretationQuantitative assessment of the contribution of the external fixator is important as overloading of the callus due to insufficient support has been implicated in the retardation of the healing process.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , ,