Article ID Journal Published Year Pages File Type
4055222 Foot and Ankle Surgery 2009 6 Pages PDF
Abstract

BackgroundBiodegradable fixation implants have been developed to avoid secondary hardware removal. The aim of this study was to retrospectively follow-up ankle fracture patients treated with a biodegradable plate and screws, and to evaluate the clinical outcome and occurrence of complications.MethodsFifty-seven ankle fracture patients treated with biodegradable implants were invited, and a total of 50 were available to participate in this study. The follow-up included a review of each patient's medical records, evaluation of radiographs, fracture reduction classification, and functional scoring.ResultsThere were 36 lateral malleolar and 14 bimalleolar fractures. No perioperative complications occurred. Average follow-up time was 17 months. All fractures healed. Fracture alignment was classified as anatomical in 49 patients and good in 1 case. The mean Olerud and Molander functional ankle score at final follow-up was 86. Eight patients had postoperative complications. These included delayed wound healing in 1 case, 3 cases of deep-vein thrombosis, and 4 soft tissue reactions.ConclusionsAccording to the results of this retrospective study, the biodegradable implants used yielded fracture healing and functional results comparable to those previously reported after conventional metal fixation.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, ,