Article ID Journal Published Year Pages File Type
4060070 The Journal of Arthroplasty 2016 5 Pages PDF
Abstract

BackgroundFiltered-exhaust helmet systems are commonplace during total joint arthroplasty, but their ability to limit intraoperative contamination has been questioned. We hypothesized that activation of the airflow system after complete gowning would lead to decreased contamination of the surgical environment.MethodsUsing a fluorescent particle model, the maximal particle spread from a filtered-exhaust helmet and contamination of the surgical environment based on timing of airflow activation through simulated surgical gowning procedures were evaluated.ResultsHelmet airflow analysis revealed particle spread greater than 5 feet in all trials. Activation before gowning resulted in a significantly greater contamination in the control group compared with the experimental group (P = .014).ConclusionsWe recommend complete surgical gowning before activation of the airflow system.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation