Article ID Journal Published Year Pages File Type
4060756 The Journal of Arthroplasty 2012 6 Pages PDF
Abstract

This study evaluated concordance between self-reports and surgeon assessments of short-term complications. A total of 3976 primary total hip arthroplasty patients consented for an institutional registry (5/2007-12/2008); 3186 (80.1%) completed a 6-month survey; 137 (4.4%) reported deep venous thrombosis, pulmonary embolism, major bleeding, fracture, or dislocation. Patients reporting complications were called. Positive predictive values and 95% confidence intervals (95% CI) for patient self-report were measured, using surgeon assessment for comparison: pulmonary embolism, 88.9% (95% CI, 78.4%-99.4%); dislocation, 81.1% (95% CI, 75.9%-86.5%); fracture, 73.7% (95% CI, 63.8%-83.5%); deep venous thrombosis, 69.7% (95% CI, 61.9%-77.5%); major bleeding, 32.0% (95% CI, 19.4%-44.5%); any bleeding, 88.0% (95% CI, 75.3%-99.9%). Of 97 confirmed complications, 64.95% presented to outside institutions. Registry data on self-reported complications may overcome limitations of traditional methods, but data should be interpreted cautiously. Concordance was high for PE and dislocation but low for major bleeding.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation