Article ID Journal Published Year Pages File Type
4062392 The Journal of Arthroplasty 2012 7 Pages PDF
Abstract

Second-generation metal-on-metal bearings have been used since the late 1980s as alternative bearings to eliminate aseptic loosening due to polyethylene wear. The aim of the present study was to evaluate the long-term results of a series of Metasul (Zimmer GmbH, Winterthur, Switzerland) metal-on-metal total hip arthroplasty (THA). One hundred forty-nine cementless THAs with a 28-mm Metasul articulation were performed in 111 consecutive patients. The results were retrospectively reviewed at 13 years postoperatively. Clinical and radiographic evaluations and implant survivorship were performed. Seven hips (4.7%) were revised. The overall survivorship with revision for any reason as the end point was 0.94. The average Harris hip score was 91.4. Expansive osteolysis was found adjacent to the stem in 4 hips. Metal wear–related aseptic loosening was not the major reason for failure in our Metasul metal-on-metal THAs. Recurrent dislocation was the main reason for revision in our series.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , ,