Article ID Journal Published Year Pages File Type
4062480 The Journal of Arthroplasty 2010 5 Pages PDF
Abstract

We aimed to investigate the factors affecting range of flexion after hip resurfacing. A total of 82 cases, operated by a single surgeon, were assessed at a mean of 43 months. The Einzel-Bild-Roentgen-Analysis for the acetabular cup software was used to measure socket orientation. Range of flexion had a moderate positive correlation with cup anteversion (R = 0.26, P = .017), weak but significant negative correlation with neck diameter (R = −0.23, P = .042), and none with anterior femoral head-neck offset. Using multivariate analysis that adjusted for age, sex, cup anteversion and inclination, head-neck offset ratio, head-neck ratio, and neck diameter, the only significant correlate of flexion was cup anteversion (P = .017). Care should be taken during cup placement to allow adequate anteversion to be maintained in Birmingham hip resurfacing because this can affect flexion range of motion.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , ,