Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4062701 | The Journal of Arthroplasty | 2011 | 13 Pages |
Abstract
A total of 208 patients were enrolled in a multicenter, prospective randomized, institutional review board-approved study that compared preoperative surgical plan to postoperative 2-dimensional radiographic alignment measured by a blinded reviewer for primary total knee arthroplasty (TKA) implanted using computer-assisted surgery (CAS) compared with conventional TKA instrumentation. The results demonstrated a statistically significant improvement in the coronal tibial component alignment (P < .03) and failed to demonstrate a statistically significant improvement in the mechanical axis, femoral coronal/sagittal, and tibial sagittal alignment. Knee Society Score knee and function scores and 6-minute walk test were equivalent between the 2 treatment groups at all postoperative intervals. There was a statistically significant increase in the skin-skin time (P < .0001) and the time until first bone cut (P < .0001) for the CAS knees compared with those implanted with conventional instrumentation. The use of CAS in this randomized clinical trial conducted at high-volume centers did not offer a clinically meaningful improvement in postoperative alignment, clinical, functional, or safety outcomes compared with conventional TKA.
Keywords
Related Topics
Health Sciences
Medicine and Dentistry
Orthopedics, Sports Medicine and Rehabilitation
Authors
William P. MD, J. Bohannon MD, Joseph T. MD, David F. MD, Ali MD, David A. MD,