Article ID Journal Published Year Pages File Type
4063223 The Journal of Arthroplasty 2009 10 Pages PDF
Abstract

To compare the effectiveness of computer-assisted surgery (CAS) and mechanical jig technique in hip resurfacing arthroplasty, we reviewed 176 hip resurfacing arthroplasty performed in 158 patients. The initial 131 hips were resurfaced using the conventional mechanical jig technique, and the remaining 45 hips with the CAS technique. The demographic data of the patients were similar for both techniques. Follow-up radiographs taken 2 months after the surgery showed patients in the CAS technique having a significantly better alignment of the femoral component on the frontal and sagittal planes. There was no difference in the risk of implant notching on the femoral neck for both techniques. The implant sizes were similar for both techniques; thus, the amount of bone stock preserved was not technique specific.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, ,