Article ID Journal Published Year Pages File Type
4063512 The Journal of Arthroplasty 2009 9 Pages PDF
Abstract

In this prospective randomized study, we investigate metal ion concentrations and clinical outcome 2 years after metal-on-metal (28 patients) or metal-on-polyethylene (26 patients) hip arthroplasty with 28-mm modular heads. Metal ion concentrations in patient serum were analyzed by high-resolution plasma mass spectrometry. The clinical outcome was almost identical in both groups with respect to the Harris hip score and the Medical Outcome Study Short Form–36; and on plain radiography, no signs of loosening occurred in any group. In the metal-on-metal group, concentrations of all investigated ions increased significantly when compared with preoperative values: cobalt, 15.3-fold (95% confidence interval [CI], 9.4-21.2); chromium, 5.2-fold (CI, 3.5-7.0); nickel, 2.1-fold (CI, 1.2-3.0); and manganese, 1.6-fold (CI, 1.3-2.0). In the metal-on-polyethylene group, a smaller but significant increase in the concentrations of cobalt and nickel occurred, whereas concentrations of the other ions did not change significantly.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , ,