Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4063549 | The Journal of Arthroplasty | 2008 | 7 Pages |
Abstract
In this series, a failed first-generation patellofemoral arthroplasty was revised to a second-generation prosthesis. Fourteen knees were prospectively followed up for a mean of 60 months. Primary procedure failure was due to component malposition, subluxation, polyethylene wear, or overstuffing. Mean Bristol knee scores improved from 58 (range, 36-86) to 79 (range, 38-100) (P < .001). Mild femorotibial arthritis (Ahlbach stage I) was present in 5 knees and predicted a poorer outcome. At most recent follow-up, there was no evidence of wear, loosening, or subluxation. Significant improvement can be obtained when revising the failed patellofemoral arthroplasty, provided there is no femorotibial arthritis.
Related Topics
Health Sciences
Medicine and Dentistry
Orthopedics, Sports Medicine and Rehabilitation
Authors
Michiel R.G. Hendrix, Christopher E. Ackroyd, Jess H. Lonner,