We have developed an intraoperative model to quantify total hip arthroplasty impingement and dislocation mechanics using fluoroscopy and shape-matching techniques. Two patient groups were investigated: group 1 consisted of 12 hips using 28- or 32-mm femoral heads and an anterolateral surgical approach, and group 2 consisted of 17 hips using 22- or 26-mm femoral heads and a posterolateral surgical approach. During intraoperative hip stability testing consisting of extension and external rotation motions, group 1 was more unstable, and prosthetic impingement was the major reason for dislocation. With flexion and internal rotation motions, group 2 was more unstable, and superior-lateral impingement or soft tissue traction was the major reason for dislocation. Intraoperative quantitative assessment of hip mechanics provides a safe and clinically relevant method to characterize potential complications and evolve techniques to prevent them.