Article ID Journal Published Year Pages File Type
4064244 The Journal of Arthroplasty 2007 6 Pages PDF
Abstract

Periprosthetic fractures involving a total knee arthroplasty pose a challenging treatment problem with a prevalence of up to 2.5% in the literature (Instr Course Lect 2001;50:379-389). The supracondylar region of the femur is commonly involved, often with minimal available bone in contact with the components. The clinical challenges are particularly more complex in the case of a combined distal femoral and proximal tibial periprosthetic fracture. This injury is considered a “floating prosthesis” injury because of the complete separation of the prosthesis from the remaining skeleton. In this report, a floating prosthesis injury, in combination with a femoral shaft fracture, is treated with 2 locking plates using a minimally invasive technique, with limited blood loss, immediate pain relief after surgery, and successful healing of all fractures with minimal deformity.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , ,