Abstract

PurposeTo test the mechanical stability and histologic osseointegration under load-bearing conditions of 2 different materials, pyrocarbon (Py) and titanium (Ti), in a rabbit model.MethodsProximal interphalangeal implants (9 Ti, 8 Py) were placed into rabbit knees and the animals were killed after 3 months. Subsidence was assessed by monthly x-rays. Mechanical stability was measured with a nondestructive pullout test. Implant osseointegration was evaluated by an analysis of the relative implant–calcified bone contact surface on microradiographs and by a histomorphometric analysis of the percentage of bone and connective tissue contact with the implant surface. Histologic examination included assessment of bone apposition on the basis of fluorochromes.ResultsSubsidence was found in all 8 Py implants but in none of the Ti group. All 9 Ti implants were mechanically stable; all 8 Py implants were loose. A significantly higher implant–bone contact was found for the Ti group compared with the Py group. Bone apposition increased with time and was highest for the Ti implants 6 weeks after implantation.ConclusionsIn the rabbit model osseointegration of implants was highly dependent on the material. A reliable osseointegration was found for Ti implants. For Py implants no osseointegration or implant stability was achieved. For use of small joints of the hand we therefore recommend Ti-based implants.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , , ,