Article ID Journal Published Year Pages File Type
4099312 The Spine Journal 2009 8 Pages PDF
Abstract

Background contextAnterior corpectomy and reconstruction with bone graft and a rigid screw-plate construct is an established procedure for treatment of cervical neural compression. Despite its reliability in relieving symptoms, there is a high rate of construct failure, especially in multilevel cases.PurposeThere has been no study evaluating the biomechanical effects of screw angulation on construct stability; this study investigates the C4–C7 construct stability and load-sharing properties among varying screw angulations in a rigid plate-screw construct.Study designA finite element model of a two-level cervical corpectomy with static anterior cervical plate.MethodsA three-dimensional finite element (FE) model of an intact C3–T1 segment was developed and validated. From this intact model, a fusion model (two-level [C5, C6] anterior corpectomy) was developed and validated. After corpectomy, allograft interbody fusion with a rigid anterior screw-plate construct was created from C4 to C7. Five additional FE models were developed from the fusion model corresponding to five different combinations of screw angulations within the vertebral bodies (C4, C7): (0°, 0°), (5°, 5°), (10°, 10°), (15°, 15°), and (15°, 0°). The fifth fusion model was termed as a hybrid fusion model.ResultsThe stability of a two-level corpectomy reconstruction is not dependent on the position of the screws. Despite the locked screw-plate interface, some degree of load sharing is transmitted to the graft. The load seen by the graft and the shear stress at the bone-screw junction is dependent on the angle of the screws with respect to the end plate. Higher stresses are seen at more divergent angles, particularly at the lower level of the construct.ConclusionThis study suggests that screw divergence from the end plates not only increases load transmission to the graft but also predisposes the screws to higher shear forces after corpectomy reconstruction. In particular, the inferior screw demonstrated larger stress than the upper-level screws. In the proposed hybrid fusion model, lower stresses on the bone graft, end plates, and bone-screw interface were recorded, inferring lower construct failure (end-plate fractures and screw pullout) potential at the inferior construct end.

Related Topics
Health Sciences Medicine and Dentistry Orthopedics, Sports Medicine and Rehabilitation
Authors
, , , , , ,