Article ID Journal Published Year Pages File Type
4106973 Brazilian Journal of Otorhinolaryngology 2010 5 Pages PDF
Abstract

One of the most criticized points in tinnitus clinical studies arise from the lack of consensus about measurement methods.AimTo evaluate the correlation between audiometric thresholds, pitch matching (PM), minimum masking level (MML), Tinnitus Handicap Inventory (THI) and the Beck Depression Inventory (BDI) in tinnitus patients.Study designProspective, cross-sectional.Materials and methodsSubjects were submitted to tonal audiometry, PM and MML for tinnitus. They also filled out the THI and BDI. Data was statistically compared for correlation purposes between audiometric thresholds, psycho-acoustic measures and questionnaires.ResultsThere was no statistically significant correlation between THI and MML, both in patients with BDI scores under and over 14 points. There was no statistically significant correlation between the worst hearing frequency and PM, as well as between the cut-off frequency and the PM in patients with descending hearing curves in their audiograms.ConclusionsThere is no statistically significant correlation between psycho-acoustic measures (PM and MML), audiometric thresholds, THI and BDI. Tinnitus is a very complex symptom and isolated measures by psycho-acoustic methods; tinnitus and depression questionnaires are not satisfactory.

Related Topics
Health Sciences Medicine and Dentistry Otorhinolaryngology and Facial Plastic Surgery
Authors
, , , , ,