Article ID Journal Published Year Pages File Type
4107245 Brazilian Journal of Otorhinolaryngology 2007 10 Pages PDF
Abstract

SummaryMismatch Negativity (MMN) is used to evaluate the central auditory system.Aimto characterize the MMN, in normal subjects.Materials and Methodsprospective study, 12 subjects, six males and six females, between the ages of 18 and 24. “Mann-Whytnei” test. Exams: Pure Tone Audiometry (PTA), Tympanometry, Otoacoustic Emissions and Short and Long Latency Auditory Potentials (MMN).Resultsin MMN variable amplitude, the mean value was of −2.757 μV and −3.548 μV, CZA1 and CZA2; of 1.435 μV and −1.867 μV, CZA1 and CZA2. In variable and medium latency, we found in 150.7ms and 153.2ms, CZA1 and CZA2; in 170.4ms and 184.0ms, CZA1 and CZA2 - for females and males respectively.Conclusionrelated to latency, there was significant statistical difference between the genders in relation to CZA1 and CZA2; and it was lower for females and higher for males.

Related Topics
Health Sciences Medicine and Dentistry Otorhinolaryngology and Facial Plastic Surgery
Authors
, , , , ,