Article ID Journal Published Year Pages File Type
4118242 Journal of Plastic, Reconstructive & Aesthetic Surgery 2012 8 Pages PDF
Abstract

SummaryBackgroundTotal orbital floor reconstruction with sheet-shape materials is available for the treatment of extensive and crushed-type blowout fractures. Simple blowout fractures, on the other hand, require only manual reduction without fixation. Although several types of blowout fractures do not require total reconstruction, some fixation is usually necessary.MethodsEighteen cases of blowout fracture were treated with transzygomatic Kirschner wire fixation between 2002 and 2009. This technique was applied to simple fracture cases in which periorbital soft tissue re-herniated through the floor defect into the maxillary sinus after manual reduction, despite improvement of the extra-ocular muscle entrapment. The wire was used to directly support the fracture segment in five cases and used together with a maxillary sinus anterior wall bone graft in 13 cases.ResultsMean follow-up was 12.5 months. Mild diplopia remained as a subjective symptom in one case. None of the cases developed major complications or conspicuous scars on the cheek.ConclusionsTranszygomatic Kirschner wire fixation for blowout fracture has the advantages of precise and rigid fixation of all parts of the inferior floor, minimal morbidity without requiring an orbital approach and long-term safety without artificial remnants. This technique can be applied for the treatment of simple blowout fractures.

Related Topics
Health Sciences Medicine and Dentistry Otorhinolaryngology and Facial Plastic Surgery
Authors
, , , , , , , ,