Article ID Journal Published Year Pages File Type
4119179 Journal of Plastic, Reconstructive & Aesthetic Surgery 2011 7 Pages PDF
Abstract

SummaryClosed reduction is commonly conducted for the treatment of a nasal bone fracture unless a concurrent fracture or a severe nasal septum fracture is observed. As the reduction, however, is not conducted through the direct gross observation of the fracture site, it is difficult to obtain a good result from it. Accordingly, a supplementary process is required.Closed reduction with a C-arm was conducted within the period from March 2009 to January 2010 on 50 patients with nasal bone fractures, to treat these fractures or to evaluate the postoperative conditions of such. The usefulness of the C-arm was evaluated by comparing the aforementioned closed reduction with a C-arm with the closed reduction without a C-arm that was conducted on 64 patients with nasal bone fractures within the period from January 2008 to February 2009.The complication morbidity and re-operation rate were significantly lower in the patient group with closed reduction with a C-arm, and the radiologic examination also showed a significant difference.If closed reduction is conducted on patients with nasal bone fractures using a C-arm, an accurate result can be obtained by observing the fractured bone indirectly with continuous imaging during the operation, and the operation result can be immediately assessed in the operating room, thereby reducing the frequencies of complications and re-operation.

Related Topics
Health Sciences Medicine and Dentistry Otorhinolaryngology and Facial Plastic Surgery
Authors
, , ,