Abstract
In SSCD patients, an ABG is consistently shown at the low frequency when the dehiscence is larger than 3 mm. The size of the average ABG correlates with the size of the dehiscence. These findings highlight the effect of the dehiscence size on conductive hearing loss in SSCD and contribute to a better understanding of the symptomatology of patients with SSCD.