Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4167222 | The Journal of Pediatrics | 2008 | 5 Pages |
ObjectiveTo evaluate the efficacy of first day of life pulse oximetry screening to detect congenital heart defects (CHDs).Study designWe performed a population-based prospective multicenter study of postductal (foot) arterial oxygen saturation (SpO2) in apparently healthy newborns after transfer from the delivery suite to the nursery. SpO2 < 95% led to further diagnostic evaluations. Of 57,959 live births, 50,008 (86%) were screened. CHDs were prospectively registered and diagnosed in 658 newborns (1.1%), of whom 35 (5%) were classified as critical (ductus dependent, cyanotic).ResultsOf the infants screened, 324 (0.6%) failed the test. Of these, 43 (13%) had CHDs (27 critical), and 134 (41%) had pulmonary diseases or other disorders. The remaining 147 infants (45%) were healthy with transitional circulation. The median age for babies with CHDs at failing the test was 6 hours (range, 1-21 hours). For identifying critical CHDs, the pulse oximetry screening had a sensitivity rate of 77.1% (95% CI, 59.4-89.0), specificity rate of 99.4% (95% CI, 99.3-99.5), and a false-positive rate of 0.6% (95% CI, 0.5-0.7).ConclusionsEarly pulse oximetry screening promotes early detection of critical CHDs and other potentially severe diseases. The sensitivity rate for detecting critical CHDs is high, and the false-positive rate is low.