Abstract
												EDT technique is very sensitive to imperfect segmentations, resulting in higher variation compared to the Laplacian technique. The smooth transition between surfaces makes the Laplacian technique more robust compared to EDT for the measurement of CT gallbladder thickness.
											Keywords
												
											Related Topics
												
													Health Sciences
													Medicine and Dentistry
													Radiology and Imaging
												
											Authors
												Mithun N. PhD, Matthew S. PhD, Chiayi MD, Daniel J. MD, Michael MD, Steve MD, David MD, Jonathan MD, PhD, 
											