Article ID Journal Published Year Pages File Type
4221984 Clinical Imaging 2011 4 Pages PDF
Abstract

The purpose of this study was to investigate whether maximum nodule perimeter to the approximate oval could discriminate benign nodules from malignancy.Measurement of maximum nodule perimeter difference to the approximate oval was performed using volume-rendering images of three directions of each pulmonary nodule. The margin was then traced manually and our custom software delineated the approximate oval automatically.The maximum nodule perimeter difference was 26.5±23.3 mm for malignant and 16.6±16.9 mm for benign nodules, showing an almost statistically significant difference (P=.07).This study suggests that the maximum nodule perimeter difference to the approximate oval of the malignant nodules has a tendency to be longer than benign nodules.

Related Topics
Health Sciences Medicine and Dentistry Radiology and Imaging
Authors
, , , ,