Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4222016 | Clinical Imaging | 2014 | 7 Pages |
ObjectiveTo develop a diffusion tensor imaging (DTI) protocol for assessing the sural nerve in healthy subjects.MethodsSural nerves in 25 controls were imaged using DTI at 3 T with 6, 15, and 32 gradient directions. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were computed from nerve regions of interest co-registered with T2-weighted images.ResultsCoronal images with 0.5(RL)×2.0(FH)×0.5(AP) mm3 resolution successfully localized the sural nerve. FA maps showed less variability with 32 directions (0.559±0.071) compared to 15(0.590±0.080) and 6(0.659±0.109).ConclusionsOur DTI protocol was effective in imaging sural nerves in controls to establish normative FA/ADC, with potential to be used non-invasively in diseased nerves of patients.