Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4230787 | Journal of the American College of Radiology | 2013 | 5 Pages |
Abstract
Requests for vascular access at the MUHC have been standardized and centralized. Single-lumen catheters are inserted unless a specific indication for a dual-lumen catheter is provided. To date, data have been collected on >4,000 catheter insertions, both before and after the switch to the single-lumen program. Dual-lumen catheters have been required in only 50% of cases. Reinsertion rates have decreased, leading to the first year-over-year reduction in peripherally inserted central venous catheter insertion since data collection began in 2002. The program has also resulted in significant reductions in central line-associated bloodstream infection and catheter-related thrombosis. Decreased maintenance and reinsertion costs have led to overall savings for the MUHC of approximately $1.1 million.
Keywords
Related Topics
Health Sciences
Medicine and Dentistry
Radiology and Imaging
Authors
Jeremy MD, France RN, MSc, Richard MD, David MD,