Article ID Journal Published Year Pages File Type
4279369 The American Journal of Surgery 2013 6 Pages PDF
Abstract

BackgroundDamage-control surgery frequently results in open abdomen. The objective of this study was to determine whether resuscitation with goal-directed fluid therapy (GDT) using “dynamic” hemodynamic indices via modern pulse contour analysis devices such as the FloTrac Vigileo monitor leads to lower fluid requirements, subsequent quicker abdominal closure, and overall improved outcomes in these patients.MethodsPatients admitted to the surgical intensive care unit with open abdomen were retrospectively reviewed. Those resuscitated with Vigileo-guided GDT were matched to those resuscitated by static clinical parameters.ResultsTotal fluid intake and vasopressor requirements were similar in both groups. GDT with the Vigileo allowed earlier lactate clearance and reduced the number of days until abdominal wall closure by an average of .99 days.ConclusionsVigileo-mediated GDT did not affect fluid volume or vasopressor use in open abdomen patients, but facilitated more effective resuscitation and decreased the number of days to fascial closure, leading to shorter hospital stays. Vigileo-mediated GDT, therefore, may improve overall outcomes in open abdomen patients.

Related Topics
Health Sciences Medicine and Dentistry Surgery
Authors
, , , , , , , , ,