Article ID Journal Published Year Pages File Type
4292528 Journal of the American College of Surgeons 2010 6 Pages PDF
Abstract

BackgroundContinuous ambulatory peritoneal dialysis (CAPD) catheters provide a preferred alternative to hemodialysis in a growing population with chronic kidney disease. However, CAPD catheters traditionally have been associated with a high rate of nonfunction with both open and laparoscopic procedures. New advanced laparoscopic techniques using rectus sheath tunneling and omentopexy have been reported to improve catheter function.Study DesignThis study retrospectively reports the Cleveland Clinic experience during the transition from basic to advanced laparoscopic techniques from June 2002 to July 2008. A total of 197 patients were identified: 68 who underwent insertion with basic techniques and 129 who received catheters with advanced techniques. Primary nonfunction, procedural complications, and overall nonfunction rate were analyzed using the most recent follow-up to June 2008.ResultsPrimary nonfunction occurred in 25 of 68 (36.7%) patients in the basic group; this occurred in only 6 of 129 patients (4.6%) in the advanced group (p < 0.0001). The overall rate of complications including nonfunction from primary and secondary sources, peritoneal leak, peritonitis, port-site hernia, and bleeding occurred in 31 of 68 (45.6%) patients in the basic group and 21 of 129 (16.28%) patients in the advanced group (p < 0.0001).ConclusionsThese data clearly show a significant improvement in CAPD catheter function using omentopexy and rectus sheath tunneling. These advanced laparoscopic techniques should become the preferred method of CAPD catheter insertion.

Related Topics
Health Sciences Medicine and Dentistry Surgery
Authors
, , , ,