Article ID Journal Published Year Pages File Type
4308180 Surgery 2011 7 Pages PDF
Abstract

BackgroundThe VIO soft-coagulation system (SCS) is a new device for tissue coagulation. The current study evaluated the efficacy of the SCS when used for liver resection.MethodsThe 252 patients were divided into 2 groups; in 155 patients (conventional group), liver transection was performed using an ultrasonic dissector and saline-coupled bipolar electrocautery for hemostasis. In 97 patients (SCS group), the SCS was used instead of bipolar electrocautery.ResultsThe median blood loss and surgical time were less in the SCS group than in the conventional group (350 vs 640 mL, P = .0028; 280 vs 398 min, P < .0001). No significant differences were found in postoperative complications between the SCS group (32.0%) and the conventional group (40.6%). The risk factors for bleeding were nonuse of the SCS (P = .0039), macroscopic vascular invasion of the hepatic tumors (P = .0088), and collagen type IV value in the sera >200 (P = .0250) on multivariate analysis. In a subgroup analysis, in the collagen type IV value >200 subgroup, the tumor diameter >5 cm subgroup, and the inflow nonocclusion subgroup, use of the SCS decreased surgical bleeding (P = .0120, P = .0126, and P = .0032, respectively) and surgical time (P = .0001, P < .0001, and P = .0036, respectively) compared with the conventional group. Furthermore, even in the major hepatectomy group, the SCS use decreased surgical time (P < .0001).ConclusionThe SCS is an effective and safe device for decreasing surgical time and surgical bleeding without increasing the rate of bile leakage and causing other complications.

Related Topics
Health Sciences Medicine and Dentistry Surgery
Authors
, , , , , , , , , ,