Article ID Journal Published Year Pages File Type
4414340 Chemosphere 2008 8 Pages PDF
Abstract

In the frame of the international SOILSAMP project, funded and coordinated by the National Environmental Protection Agency of Italy (APAT), uncertainties due to field soil sampling were assessed. Three different sampling devices were applied in an agricultural area using the same sampling protocol. Cr, Sc and Zn mass fractions in the collected soil samples were measured by k0-instrumental neutron activation analysis (k0-INAA). For each element-device combination the experimental variograms were calculated using geostatistical tools. The variogram parameters were used to estimate the standard uncertainty arising from sampling. The sampling component represents the dominant contribution of the measurement uncertainty with a sampling uncertainty to measurement uncertainty ratio ranging between 0.6 and 0.9. The approach based on the use of variogram parameters leads to uncertainty values of the sampling component in agreement with those estimated by replicate sampling approach.

Related Topics
Life Sciences Environmental Science Environmental Chemistry
Authors
, , , , , , , , , , , ,