Article ID Journal Published Year Pages File Type
4424796 Environmental Pollution 2012 7 Pages PDF
Abstract

The polar organic chemical integrative sampler (POCIS) was calibrated to monitor pesticides in water under controlled laboratory conditions. The effect of natural organic matter (NOM) on the sampling rates (Rs) was evaluated in microcosms containing <0.1–5 mg L−1 of total organic carbon (TOC). The effect of hydrodynamics was studied by comparing Rs values measured in stirred (SBE) and quiescent (QBE) batch experiments and a flow-through system (FTS). The level of NOM in the water used in these experiments had no effect on the magnitude of the pesticide sampling rates (p > 0.05). However, flow velocity and turbulence significantly increased the sampling rates of the pesticides in the FTS and SBE compared to the QBE (p < 0.001). The calibration data generated can be used to derive pesticide concentrations in water from POCIS deployed in stagnant and turbulent environmental systems without correction for NOM.

► We assessed the effect of TOC and stirring on pesticide sampling rates by POCIS. ► Total organic carbon (TOC) had no effect on the sampling rates. ► Water flow and stirring significantly increased the magnitude of the sampling rates. ► The sampling rates generated are directly applicable to field conditions.

Related Topics
Life Sciences Environmental Science Environmental Chemistry
Authors
, , , , ,