Article ID Journal Published Year Pages File Type
4427509 Environmental Pollution 2007 8 Pages PDF
Abstract

A method for simultaneous quantitative determination of alkyl benzyl, dialkyl and trialkyl quaternary ammonium compounds (QACs) has been developed, validated and subsequently applied to real water samples in Austria. The method employs liquid-liquid extraction (LLE) followed by liquid chromatography/tandem mass spectrometry (LC-MS/MS), using electrospray ionization (ESI) in positive mode. The overall method quantification limits range from 4 to 19 ng/L for the enrichment of 500 mL water samples and analyte recoveries are between 80 and 99%. The method was applied to 62 of the respective water samples without filtration to avoid the loss of the analytes due to the high adsorption capacity of these compounds. Maxima in the mg/L range, especially in the wastewater of hospitals and laundries, could be detected for the selected target compounds.

Related Topics
Life Sciences Environmental Science Environmental Chemistry
Authors
, , , , , , ,