Abstract

This paper presents an objective methodology for determining the optimum number of ambient air quality stations in a monitoring network. The methodology integrates the multiple-criteria method with the spatial correlation technique. The pollutant concentration and population exposure data are used in this methodology in different ways. In the first stage, the Fuzzy Analytic Hierarchy Process (FAHP) with triangular fuzzy numbers (TFNs) is used to identify the most desirable monitoring locations. The network configuration is then determined on the basis of the concept of sphere of influences (SOIs). The SOIs are dictated by a predetermined cutoff value (rc) in the spatial correlation coefficients (r) between the pollutant concentrations at the monitoring stations identified from first step and the corresponding concentrations at neighboring locations in the region. Finally, the optimal station locations are ranked by using combined utility scores gained from the first and second steps. The expansion of air quality monitoring network of Riyadh city in Saudi Arabia is used as a case study to demonstrate the proposed methodology.