Article ID Journal Published Year Pages File Type
4456364 Journal of Environmental Sciences 2008 7 Pages PDF
Abstract

The high water content of municipal solid waste (MSW) will reduce the efficiency of mechanical sorting, consequently unfavorable for beneficial utilization. In this study, a combined hydrolytic-aerobic biodrying technology was introduced to remove water from MSW. The total water removals were proved to depend on the ventilation frequency and the temporal span in the hydrolytic stage. The ventilation frequency of 6 times/d was preferable in the hydrolytic stage. The hydrolytic span should not be prolonged more than 4 d. At this optimal scenario, the final water content was 50.5% reduced from the initial water content of 72.0%, presenting a high water removal efficiency up to 78.5%. A positive correlation was observed between the organics losses and the water losses in both hydrolytic and aerobic stages (R = 0.944, p < 0.01). The evolutions of extracellular enzyme activities were shown to be consistent with the organics losses.

Related Topics
Life Sciences Environmental Science Environmental Science (General)