Article ID Journal Published Year Pages File Type
4473328 Waste Management 2009 8 Pages PDF
Abstract

To determine the allowable ratio of waste sludge required to ensure an aerobic zone in the landfill, we investigated sludge permeability, which involved mixing sludge, the major landfill waste in Japan, at different mixing ratios with other wastes (slag and construction and demolition waste (C&D)). We measured parameters of sample permeability and analyzed parameters that exert a large influence on oxygen penetration depth with a simulation model accounting for both diffusion and convection driven by temperature gradients. We also determined the critical volumetric contents in which gas and/or water permeability change significantly when sludge is mixed with sand or gravel. From the results of the simulations, gas permeability of the layer, the difference between inside and outside temperatures and the oxygen consumption rate exert a large influence on the resulting oxygen penetration depth. The allowable ratio of sludge required to ensure an aerobic zone in the landfill was determined by considering the balance of the above three parameters. By keeping volumetric sludge content to below 25%, air convection and oxygen penetration depth of several meters were achieved in the modeling.

Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Geotechnical Engineering and Engineering Geology
Authors
, , , , ,