Article ID Journal Published Year Pages File Type
4484072 Water Research 2010 11 Pages PDF
Abstract

Lead samples were collected at the tap from homes with lead service lines (LSLs) in a full-scale utility using both random daytime (RDT) and particulate stimulation sampling (PSS) protocols. Analysis of the results revealed two sources and occurrences of particulate lead. A first source is due to corrosion of lead-bearing elements in the premise plumbing (PP) and occurs mostly at low to moderate concentrations <3 μg/L, with some sporadic higher concentrations (4–12 μg/L). These spikes were consistently observed and considerably increased using PSS, showing that current sampling protocols may miss a significant portion of particulate lead. The second source results from the adsorption of dissolved lead onto iron deposits in LSL/PP, and is continuously present at low to moderate concentrations. Statistical analyses were validated by physical analyses of: (i) lead scales from LSLs; and (ii) lead particles from tap aerators.

Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Earth-Surface Processes
Authors
, , , , ,