Article ID Journal Published Year Pages File Type
4486264 Water Research 2005 11 Pages PDF
Abstract

In order to optimise nitrogen removal in an aerobic granular sludge system, short- and long-term effects of decreased oxygen concentrations on the reactor performance were studied. Operation at decreased oxygen concentration is required to obtain efficient N-removal and low aeration energy requirement. A short-term oxygen reduction (from 100% to 50%, 40%, 20% or 10% of the saturation concentration) did not influence the acetate uptake rate. A lower aerobic acetate uptake at lower oxygen concentrations was obviously compensated by anoxic acetate uptake. Nitrogen removal was favoured by decreased oxygen concentrations, reaching a value of 34% for the lowest oxygen concentration tested. Long-term effects were evaluated at two oxygen saturation levels (100% and 40%). Nitrogen removal increased from 8% to 45% when the oxygen saturation was reduced to 40%. However, the granules started to disintegrate and biomass washout occurred. It was impossible to obtain stable granular sludge at this decreased oxygen concentration under applied conditions. A solution to obtain stable aerobic granular sludge at low oxygen concentrations is needed in order to make aerobic granular sludge reactors feasible in practice.

Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Earth-Surface Processes
Authors
, , , ,