Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4675275 | Procedia Earth and Planetary Science | 2011 | 6 Pages |
In order to realize the digitization of the shearer control system and master the magnetic performance of the shearer switched reluctance motors drive (SRD), the three-phase 12/8 switched reluctance motors (SRM) used on shearer was studied, and the distribution form of SRM magnetic field of the rotor different position angles (θ=0°, θ=8°, θ=12°, θ=16°, θ=22.5°) were analyzed basing on the finite element theory. The results indicate that: when the θ=0o, the magnetic flux density in the stator and rotor is lower, which is unsaturated state and the magnetic flux leakage is serious, and whether the self-induction magnetic leakage or the mutual inductance magnetic leakage is bigger; when the θ=8° and θ=12°, there is higher local saturation phenomenon on the magnetic pole tips; when the θ=16°, the local saturation phenomenon is relieved and the magnetic leakage is decreased; when the θ=22.5°, there is little local saturation phenomenon, and the magnetic flux leakage is very small, the self-induction magnetic leakage is nearly to zero, the mutual inductance magnetic leakage is negligible. But, there is no saturation phenomenon on the rotor yoke in any position of the rotor.