Abstract
This study uses 21 months of in-use monitored data to consider the overheating risk in a UK Passivhaus dwelling with vulnerable occupants using both static and adaptive thermal comfort assessment methods. The analysis of the data suggests the occurrence of substantial overheating according to PHPP, CIBSE Guide A and CIBSE TM52 criteria. The analysis was then expanded to consider a novel composite method to overcome the limitations of existing approaches, allowing overheating to be assessed during non-typical periods i.e. the heating season. This revealed apparent overheating during colder months, in addition to substantial night-time overheating. This has implications for the thermal comfort assessment of low energy dwellings and the design and operation of Passivhaus buildings, particularly those with vulnerable occupants.
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
M.J. Fletcher, D.K. Johnston, D.W. Glew, J.M. Parker,