Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
4921053 | Fusion Engineering and Design | 2017 | 8 Pages |
Abstract
The cryo-condensation pump used in EAST-NBI is composed of cryo-condensation panels cooled by liquid helium and radiation shields cooled by liquid nitrogen. The transmission probability of radiation shields has great influence on the performance of the cryo-condensation pump. The Monte-Carlo method is applied to simulate the trajectories of the deuterium molecules and to study the effects of the structure of the radiation shields on the transmission probability. By adding imaginary walls, the distribution of positions and flying directions of the molecules is presented. The results indicate that the uniformity of the molecules is the direct factor to influence the transmission probability.
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Chundong Hu, Bin Cheng, Yuanlai Xie, Ling Tao, Jianglong Wei, Changcheng Ma, Sihao Yang, Wei Yi,