Article ID Journal Published Year Pages File Type
4921278 Fusion Engineering and Design 2017 5 Pages PDF
Abstract
The difference between the composition of the surface and the inner part of the LiSn sample was studied using Calibration Free Laser Induced Breakdown Spectroscopy (CF-LIBS) method. The sample was analysed under the low pressure (1330 Pa) in Ar atmosphere. The spectra were record using Echelle spectrometer (Mechelle ME5000). Gate delay and gate width was optimised and set to 300 ns. In order to analyse depth profile the LIBS spectra was recorded after each laser shot. The electron density analysed by laser induced plasma was determined separately for each laser shot, which means for each ablated layer of investigated sample. The difference between the individual shots taken at distinct sites of the sample are shown. The CF-LIBS method was used to determine the elemental composition near the surface and in the central part of the LiSn sample.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , , , ,